Design-Build Process with Fire Repellent Materials for Fire-Prone Areas in California

1. Project Planning & Risk Assessment

Before any design begins, the first step is understanding the site-specific fire risks:

  • Wildfire zone classification per CAL FIRE maps.

  • Topography, vegetation, and prevailing wind patterns.

  • Local building codes, especially the California Building Code (CBC) Chapter 7A, which governs construction in the Wildland-Urban Interface (WUI).

Deliverable: A fire risk assessment report and a fire-resilient strategy plan.

2. Design Phase: Fire-Resilient Architecture

a. Site Layout and Landscaping

  • Create defensible space zones (0–5 feet, 5–30 feet, 30–100 feet).

  • Position structures away from dense vegetation or slope ridgelines.

  • Use fire-resistant plants and non-combustible ground covers (e.g., decomposed granite, gravel).

b. Architectural Design Considerations

  • Minimize exposed eaves, overhangs, and complex rooflines to reduce ember intrusion.

  • Use metal mesh screens on vents and openings more than 1/8”.

  • Integrate automatic fire shutters for windows in high-risk zones.

3. Material Selection: Fire-Resistant Building Envelope

a. Roof

  • Class A rated roofing (per ASTM E108).

  • Common fire-resistant materials:

    • Metal roofing (steel, aluminum).

    • Clay or concrete tiles.

    • Composite shingles with fire-resistant core.

b. Siding

  • Fiber-cement board (e.g., James Hardie products).

  • Stucco (non-combustible).

  • Brick or stone veneer.

Avoid vinyl siding, which melts and exposes wall cavities to embers.

c. Windows and Glazing

  • Tempered glass (2x more resistant than regular glass).

  • Multi-pane assemblies (dual/triple glazing).

  • Aluminum or steel frames (vs. wood or vinyl).

d. Doors

  • Solid core wood (≥ 1 ¾ inch), metal, or fiberglass.

  • Garage doors: Insulated and tightly sealed to prevent ember entry.

e. Decking

  • Non-combustible decking materials:

    • Metal decking.

    • Fire-rated composite decking.

    • Concrete patios or pavers as alternatives.

Avoid untreated wood or plastic-based decking.

4. Construction Phase

a. Pre-Construction

  • Confirm fire-safe compliance through local permitting.

  • Ensure all contractors are trained on WUI construction standards.

b. On-Site Execution

  • Control and minimize fire hazards during construction (hot work permits, spark shields).

  • Install fire-blocking within concealed framing areas.

  • Carefully seal penetrations and joints to block ember intrusion.

5. Inspection & Quality Assurance

  • Local building inspector verification against CBC Chapter 7A and local amendments.

  • Special inspection of vents, eaves, and concealed spaces for ember resistance.

  • Post-construction walkthrough to confirm defensible space measures.

6. Maintenance & Long-Term Safety

  • Regular inspection of roof and gutters (remove debris).

  • Maintain defensible zones with seasonal vegetation clearance.

  • Update materials or fire suppression systems (e.g., exterior sprinklers) as new tech becomes available.

✅ Summary

Key Fire-Repellent Materials:

Element Preferred Material Options

Roof Class A metal, tile, composite

Siding Fiber cement, stucco, masonry

Windows Tempered, multi-pane, metal-framed

Doors. Solid core, metal-clad

Decks Fire-rated composite, metal, concrete

Critical Codes to Follow:

  • California Building Code Chapter 7A

  • CAL FIRE Defensible Space Regulations

  • NFPA 1144 (for wildfire-prone areas)

Debra Norman